Features of the Burdick Eclipse 850 ECG System:



  • Automatic, manual or 12-lead rhythm operation for maximum flexibility

  • Easy-to-read, backlit preview screen allows patient monitoring

  • Optional, powerful interpretation algorithm includes five factors as well as pediatric analysis and pacemaker enhancement for a second opinion you can really count on

  • AccuPrint restricts ECG printout when leads are not attached correctly, ensuring a clear printout and eliminating retakes

  • Paperless storage capabilities available with data management


Technical Specifications:



  • Dimensions: 11.75" x 18.16" x 4.14" (299 x 462 x 105 mm)

  • Weight:14.2 lbs (6.45 Kg)

  • Display Backlit 320 x 240 LCD

  • Keyboard: Full alphanumeric keypad Input/output:  Compact flash (proprietary true IDE); Units w/communications Serial RS-232; Telephone line interface (RJ11C); Analog/TTL/ExTOL output (25 pin D)

  • Data:  storage 40 patient records

  • Power requirements:  AC operation: 115/230 V AC +/-10%, 0.80/0.40 A, 50/60 Hz; Fuses: For 115 V, 1.0A, 250 V type T; for 230 V, 0.5A 250 V type T; Battery operation: 16.8V NiCad rechargeable battery pack (80 minutes w/o printing or 40 minutes w/ 40 ECGs)

  • Printout:  Printout device: 216 mm thermal dot array; Paper dimensions: 8.5" x 11" (US letter) or 210 mm x 300 mm (A4); Paper type: Thermal sensitive; Chart speeds: 10, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV; 10 mm/mV limb with 5 mm/mV chest; 20 mm/mV limb with 10 mm/mV chest; Printout formats: Standard or cabrera 3, 4, 6 or 12 channel; additional rhythm formats

  • Acquisition: Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Frank X, Y, Z, Cabrera, and Nehb D, A, J; Interpretation (option): Diagnosis, measurements, reason statements; Modes: Automatic, rhythm or manual; Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard; Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard; Electrode offset tolerance: +/-300 mV; A/D conversion: 10 μV LSB; Artifact filter response: 40 Hz, -3db; Data resolution: 500 samples/second, 5 μV

  • Environmental specifications: Operating temperature: 50°F to 104°F (10°C to 40°C); Operating relative humidity: 25% to 95%, non-condensing; Operating atmospheric pressure: 700 KPa to 1060 KPa; Storage temperature: -4°F to 131°F (-20°C to 55°C); Storage relative humidity: 25% to 95%, non-condensing; Storage atmospheric pressure: 700 KPa to 1060 KPa

  • Conforms to standards:  EN60601-1:1999 / CSA C22.2 no. 601-1-M90 UL2601-1 EN60601-2-25 / CSA C22.2 no. 601-2-25 EN60601-1-2:1993

  • Safety:  Leakage current: Patient <10 μA, chassis <100 μA; Defibrillation protection: to 5000 V, 400J